{"id":1802,"date":"2014-05-11T09:30:53","date_gmt":"2014-05-11T07:30:53","guid":{"rendered":"https:\/\/www.binder-gmbh.at\/competence-in-technology\/"},"modified":"2015-12-18T10:31:53","modified_gmt":"2015-12-18T09:31:53","slug":"competence-in-technology","status":"publish","type":"page","link":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/","title":{"rendered":"Competence in Technology"},"content":{"rendered":"<blockquote><p><span style=\"color: #000000;\"><br \/>\nTechnology always develops from the primitive to the complicated and than to the simple<br \/>\n(Antoine Saint-Exup\u00e9ry)<\/span><\/p><\/blockquote>\n<p>&nbsp;<br \/>\nBINDER offers a wide range of different heating solutions, starting from warm to hot water, to air-to-air heat exchangers, to saturated steam boilers, to combustion chamber only solutions. The biggest advantage of BINDER is total flexibility. True to the motto &#8220;Nothing is impossible&#8221; our engineers will seek to provide an optimum solution for your requirements.<\/p>\n<p>Below you will find an overview for the available standard boiler sizes provided by BINDER. If you have any questions regarding special solutions please contact our sales department.<\/p>\n<h4>Boiler Range<\/h4>\n<p>Below an overview of available boiler capacities and model ranges. Also included are the available combustion units.<br \/>\n<img decoding=\"async\" src=\"\/wp-content\/uploads\/2014\/07\/leistungsgroesse_en.png\" alt=\"leistungsgroesse_en\" width=\"800\" height=\"484\" class=\"aligncenter size-large wp-image-892\" \/><\/p>\n<p><h4>System overview<\/h4>\n<p>A BINDER boiler type RRK 400-600 in combination with an moving grate combustion unit SRF:<\/p>\n<table width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"3\" bgcolor=\"c6c6c6\">\n<tr>\n<td align=\"center\" colspan=\"4\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2014\/05\/schnittbild_ges_neu_gray.png\" alt=\"schnittbild_ges_neu_gray\" width=\"800\" height=\"571\" class=\"aligncenter size-full wp-image-1134\" srcset=\"https:\/\/www.binder-gmbh.at\/wp-content\/uploads\/2014\/05\/schnittbild_ges_neu_gray-300x214.png 300w, https:\/\/www.binder-gmbh.at\/wp-content\/uploads\/2014\/05\/schnittbild_ges_neu_gray.png 500w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\n<\/td>\n<\/tr>\n<td valign=\"top\" width=\"5%\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/1.png\" alt=\"1\" width=\"30\" height=\"30\" \/><\/td>\n<td width=\"45%\" valign=\"top\"><strong>Heat Exchanger<\/strong><br \/>\n    best-practise chamfered and root welded, individually replaceable if required<\/td>\n<td width=\"5%\" valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/2.png\" alt=\"2\" width=\"30\" height=\"30\" \/><\/td>\n<td width=\"45%\" valign=\"top\"><strong>Refractory<\/strong><br \/>\n      with standard firebricks instead of manufacturer specific moulded bricks:<br \/>\n      simple and cheap to replace<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/3.png\" alt=\"3\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Heat Exchanger Cleaning<\/strong><\/p>\n<ul>\n<li>unique high-velocity flue gas circulation system<\/li>\n<li>avoids emission peaks generated by compressed air blasts<\/li>\n<li>automatic de-ashing in preset intervals, with cleaning effect over the entire tube length<\/li>\n<li>no interference with combustion process<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/4.png\" alt=\"4\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Water-cooled Boiler Jacket<\/strong><\/p>\n<ul>\n<li>absorbs the heat from the combustion chamber (heat exchanger&#8217;s first pass)<\/li>\n<li>preheats the return flow via a duct along the boiler jacket<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/5.png\" alt=\"5\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Secondary Air Supply<\/strong><br \/>\n      \u03bb-controlled, with optimized arrangement of nozzles for superior turbulent flow\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/6.png\" alt=\"6\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Radiation Arch<\/strong><br \/>\n      optimized air flow, completely lined with refractory brickwork\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/7.png\" alt=\"7\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Grate Screen<\/strong><br \/>\n      prevents ash-auger damage by falling debris\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/8.png\" alt=\"8\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Combustion Chamber<\/strong><\/p>\n<ul>\n<li>stochiometrically designed three zone system<\/li>\n<li>completely lined with refractory brickwork<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/9.png\" alt=\"9\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Anti-Burnback Provisions<\/strong><\/p>\n<ul>\n<li>controlled negative pressure inside the combustion unit<\/li>\n<li>thermostatic sensor intervening PLC routine<\/li>\n<li>direct-acting thermostatic water dousing system<\/li>\n<li>certified power failure protected damper or rotary air valve<\/li>\n<li>monitored fuel barrier or 2-fold mechanical separation<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/10.png\" alt=\"10\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Feeding System<\/strong><\/p>\n<ul>\n<li>Stoker auger or<\/li>\n<li>hydraulic feed system<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/11.png\" alt=\"11\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Moving Grate Boiler &gt;150 kW<\/strong><\/p>\n<ul>\n<li>industrial-scale solution available for commercial applications<\/li>\n<li>fuel is evenly distributed and pre dried<\/li>\n<li>automatic de-ashing into a single ash receptacle<\/li>\n<li>powered by heavy-duty hydraulic or electro-mechanical unit<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/06\/12.png\" alt=\"12\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Primary Air Supply<\/strong><br \/>\n      \u03bb-controlled, with load-dependent distribution to combustion and burnout zone\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/05\/13.png\" alt=\"13\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Industrial Quality<\/strong><\/p>\n<ul>\n<li>Wall thickness (standard):<br \/>\n  Heat Exchanger      6 mm<br \/>\n  Boiler base   10 bzw. 5 mm<\/li>\n<li>heavy-duty cleaning doors and inspection apertures, functionally arranged<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/05\/14.png\" alt=\"14\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Ash Auger<\/strong><br \/>\n      for removal of ash into the central receptacle optional with ash lock or hydraulic de-ash ram\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/05\/15.png\" alt=\"15\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Ash Scraper<\/strong><br \/>\n      for de-ashing of the entire boiler base\n<\/td>\n<td valign=\"top\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-1029\" src=\"\/wp-content\/uploads\/2014\/05\/16.png\" alt=\"16\" width=\"30\" height=\"30\" \/><\/td>\n<td valign=\"top\"><strong>Grate Element<\/strong><br \/>\n      made of high temperature cast chromium alloy, separately replaceable\n<\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Technology always develops from the primitive to the complicated and than to the simple (Antoine Saint-Exup\u00e9ry) &nbsp; BINDER offers a wide range of different heating solutions, starting from warm to hot water, to air-to-air heat exchangers, to saturated steam boilers, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1802","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Competence in Technology - BINDER Energietechnik GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Competence in Technology - BINDER Energietechnik GmbH\" \/>\n<meta property=\"og:description\" content=\"Technology always develops from the primitive to the complicated and than to the simple (Antoine Saint-Exup\u00e9ry) &nbsp; BINDER offers a wide range of different heating solutions, starting from warm to hot water, to air-to-air heat exchangers, to saturated steam boilers, [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/\" \/>\n<meta property=\"og:site_name\" content=\"BINDER Energietechnik GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/binderenergietechnik\" \/>\n<meta property=\"article:modified_time\" content=\"2015-12-18T09:31:53+00:00\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/\",\"url\":\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/\",\"name\":\"Competence in Technology - BINDER Energietechnik GmbH\",\"isPartOf\":{\"@id\":\"https:\/\/www.binder-gmbh.at\/en\/#website\"},\"datePublished\":\"2014-05-11T07:30:53+00:00\",\"dateModified\":\"2015-12-18T09:31:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.binder-gmbh.at\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Competence in Technology\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.binder-gmbh.at\/en\/#website\",\"url\":\"https:\/\/www.binder-gmbh.at\/en\/\",\"name\":\"BINDER Energietechnik GmbH\",\"description\":\"BINDER Energietechnik GmbH, Industrie Biomassefeuerungsanlagen, Warmwasser, Hei\u00dfwasser, Sattdampf, Luftw\u00e4rmtauscher, Komplettanbieter f\u00fcr erneuerbare Energiel\u00f6sungen\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.binder-gmbh.at\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Competence in Technology - BINDER Energietechnik GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/","og_locale":"en_US","og_type":"article","og_title":"Competence in Technology - BINDER Energietechnik GmbH","og_description":"Technology always develops from the primitive to the complicated and than to the simple (Antoine Saint-Exup\u00e9ry) &nbsp; BINDER offers a wide range of different heating solutions, starting from warm to hot water, to air-to-air heat exchangers, to saturated steam boilers, [&hellip;]","og_url":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/","og_site_name":"BINDER Energietechnik GmbH","article_publisher":"https:\/\/www.facebook.com\/binderenergietechnik","article_modified_time":"2015-12-18T09:31:53+00:00","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/","url":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/","name":"Competence in Technology - BINDER Energietechnik GmbH","isPartOf":{"@id":"https:\/\/www.binder-gmbh.at\/en\/#website"},"datePublished":"2014-05-11T07:30:53+00:00","dateModified":"2015-12-18T09:31:53+00:00","breadcrumb":{"@id":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.binder-gmbh.at\/en\/competence-in-technology\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.binder-gmbh.at\/en\/"},{"@type":"ListItem","position":2,"name":"Competence in Technology"}]},{"@type":"WebSite","@id":"https:\/\/www.binder-gmbh.at\/en\/#website","url":"https:\/\/www.binder-gmbh.at\/en\/","name":"BINDER Energietechnik GmbH","description":"BINDER Energietechnik GmbH, Industrie Biomassefeuerungsanlagen, Warmwasser, Hei\u00dfwasser, Sattdampf, Luftw\u00e4rmtauscher, Komplettanbieter f\u00fcr erneuerbare Energiel\u00f6sungen","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.binder-gmbh.at\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/pages\/1802","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/comments?post=1802"}],"version-history":[{"count":1,"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/pages\/1802\/revisions"}],"predecessor-version":[{"id":2920,"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/pages\/1802\/revisions\/2920"}],"wp:attachment":[{"href":"https:\/\/www.binder-gmbh.at\/en\/wp-json\/wp\/v2\/media?parent=1802"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}